Adjustment
13 - 17
13.05.14 Presser foot clearance
Requirement
1. When the automatic presser foot lift is operated, the clearance between the presser foot
and the needle plate should be 7 mm.
2. When the hand lever is raised, the clearance between the presser foot and the needle
plate should be 5 mm.
Adjust solenoid 1 (screw 2) in accordance with requirement 1.
Raise the hand lever and place adjustment gauge 3 (part no. 61-111 639-70) under the
presser foot in accordance with requirement 2.
Move presser bar lifting lever 4 against lifting piece 5.
Make sure that the needle is in the centre of the presser foot.
Fig. 13 - 15
2
1
7 mm
5 mm
3
4
5