Adjustment
13 - 36
13
.11.03 List of parameters
Group
Parameter
Description
User level
Setting range
Set value
0
10 Bobbin thread monitor-current level C 8 - 16 12
11 Bobbin thread monitor-stitch counter (starting
value)
C 0 - 255 32
1
100 Control panel contrast [%] A 90 - 110 100
101 Control panel key response signal
0=tone off/1=tone off/key inverted
2=tone on/3=tone on/key inverted
A 0 - 3 2
102 Start backtacks forwards C 0 - 9 3
103 Start backtacks in reverse C 0 - 9 3
105 Start backtacks speed B 100 - 1500 900
106 Start backtacks speed
ON = pedal-controlled
OFF = set with param. "105"
C ON - OFF OFF
107 Pedal-controlled speed start backtacks
ON = limited with parameter "105"
OFF = limited with parameter "607"
C ON - OFF OFF
108 End backtacks in reverse C 0 - 9 3
109 End backtacks forwards C 0 - 9 3
110 End backtacks speed B 100 - 1500 1000
111 No. of stitches from bright light barrier to
seam end in manual sewing
A 1 - 255 6
113 Start with light barrier
ON = only when light barrier is dark
OFF = also when light barrier is bright
B ON - OFF ON
114 After light barrier or stitch counting
ON = stop
OFF = autom. end backtacks and seam end
C ON - OFF OFF
116 Soft start stitches (soft start) A 0 - 10 1
117 Speed for soft start stitches B 180 - 1200 400
148 Start backtacks
ON = double / OFF = single
A ON - OFF ON
149 End backtacks
ON = double / OFF = single
A ON - OFF ON