PG DRIVES TECHNOLOGY AC TRACTION – DIAGNOSTICS
4 Further Status Information
The status information, 2.10 Accelerator Slip Demand, also relays some operational status data about the controller. This is in the
form of a two-letter abbreviation that replaces the “Hz” on the Programmer’s screen. These abbreviations are listed below.
N: Neutral, i.e. no drive demand and controller is not pulsing.
FD: Forward Drive, i.e. controller is applying forward drive to the motor.
FL: Forward Drive Left controller in dual motor configuration.
FR: Forward Drive Right controller in dual motor configuration.
RD: Reverse Drive, i.e. controller is applying reverse drive to the motor.
RL: Reverse Drive Left controller in dual motor configuration.
RR: Reverse Drive Right controller in dual motor configuration.
DB: Direction Braking, i.e. the controller is braking as the result of a direction change.
NB: Neutral Braking, i.e. the controller is braking as a result of a neutral drive demand.
FB: Footbraking, i.e. the controller is braking as a result of the Footbrake being operated.
HH: Hill hold i.e. the controller is holding the vehicle stationary on a hill.
HF: Restrained hill hold in the forward direction, i.e. the controller is limiting the roll-away speed of the vehicle.
HR: Restrained hill hold in the reverse direction, i.e. the controller is limiting the roll-away speed of the vehicle.
SB: Standby, i.e. the controller is in a standby condition.
The status information, 2.11 Damped Slip Demand, also relays some status data about the controller. Again, this is in the form of
a two-letter abbreviation that replaces the “Hz” on the Programmer’s screen. These abbreviations are listed below.
SM: Maximum Speed, i.e. maximum speed is available, no limits or interlocks active.
S1: Speed Limit 1 is active.
S2: Speed Limit 2 is active.
S3: Speed Limit 3 is active.
S4: Not used.
S5: Not used.
S6: Not used.
SI: Inching Speed is being applied.
SB: BDI Speed Limit is being applied.
SD: Dual Motor Speed Limit is being applied.
CL: Current Limit, i.e. the controller is in drive current limit mode.
BL: Brake Current Limit, i.e. the controller is in braking current limit mode.
CT: Controller Temperature, i.e. the controller has reduced its output due to a high heatsink temperature.
MT: Motor Temperature, i.e. the controller has reduced its output due to a high motor temperature.
The status information 2.12 Motor Voltage, also relays the current error code. This is in the form of an abbreviation as shown
below.
Fxx: Error Code, where ‘xx’ denotes the specific error.
SK79646-01 43

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PG Drives Technology SIGMADRIVE Series and is the answer not in the manual?

PG Drives Technology SIGMADRIVE Series Specifications

General IconGeneral
BrandPG Drives Technology
ModelSIGMADRIVE Series
CategoryController
LanguageEnglish

Related product manuals