Configuration and diagnostics
7278_en_04 PHOENIX CONTACT 3-5
The period of time can be set using the "flWorkFWCtrlLoginExpire" SNMP object within a
range of 30 s to 3600 s (default 300 s).
The concept is valid for the first ten users. All further users must confirm each modification
of the configuration with the password.
3.2.3 Functions/information in WBM
The navigation tree provides direct access to the following four areas:
General Instructions
Basic information about WBM.
Device Information
General device information.
General Configuration
General device configuration.
Switch Station
Device-specific configuration and diagnostics.