FL SWITCH LM ...
3-42
PHOENIX CONTACT 7278_en_04
flWorkFWCtrlPasswdSet
flWorkFWCtrlPasswdSuccess
flWorkFWCtrlLoginExpire
flWorkFWCtrlUpdate
OID 1.3.6.1.4.1.4346.11.11.11.2.4
flWorkFWCtrlTftpIpAddr
OID 1.3.6.1.4.1.4346.11.11.11.2.3.1
Syntax Octet string (2 - 24)
Access Read/write
Description A new password can be entered here with a maximum of 12 characters. Example:
- Your new password should be "factory3".
- The password must be entered a second time for confirmation.
- Your entry "factory3factory3".
- Your password for write access is now: "factory3".
For security reasons, the response is
always "*****" for read access.
OID 1.3.6.1.4.1.4346.11.11.11.2.3.2
Syntax Integer
Access Read
Description A message is displayed, which informs you whether the last change of password was
successful:
- Not changed 1
- Failed 2
- Successful 3
OID 1.3.6.1.4.1.4346.11.11.11.2.3.3
Syntax Integer32 (30 - 3600)
Access Read/write
Description Here, the number of seconds between two password entries is specified. After the time has
elapsed, the password must be re-entered, if required.
Default 300
Range 30 - 3600
OID 1.3.6.1.4.1.4346.11.11.11.2.4.2
Syntax IP address
Access Read/write
Description This object can be used to set the IP address of the TFTP server.