Commissioning
OperatingManualPNOZs50
1002194EN02
41
6.2.5.4 Statusdisplayandconfiguration
Level1:Statusindicators
Overview Display Description
PNOZs50C
Startdisplay
PNOZs50Devicename
O1,O2–Outputsofthe
powercircuitsO1andO2
Y1,Y2–Standardinputsof
feedbackloops1and2.
Counter
Numberofoperations
1:CounterforoutputO1+/
O1
2:CounterforoutputO2+/
O2
Systeminfo
Systeminfo
SW . .
Parameter CRC
0 x
SW:Softwareversionof
device,e.g.01.01.0001
ParameterCRC:Check
sumcoveringthedevice
configuration
Input
Statesoftheinputsaredis
played
Input
Y10 Y20
Y11 Y21
S35 S36
Y10Failsafeinput0forfast
shutdown,powercircuit1
Y11Failsafeinput1forfast
shutdown,powercircuit1
Y20Failsafeinput0forfast
shutdown,powercircuit2
Y21Failsafeinput1forfast
shutdown,powercircuit2
S35Standardinputfor
slowshutdown,powercircuit
1
S36Standardinputfor
slowshutdown,powercircuit
2
Feedback
Statesofthefeedbackloops
aredisplayed
Y1Standardinputforfeed
backloop1
Y2Standardinputforfeed
backloop2
Output
Statesoftheoutputsaredis
played
O1Failsafeoutputfor
powercircuit1
O2Failsafeoutputfor
powercircuit2
O3Failsafeoutputforfault
signal
O4Failsafeoutputfor
statusofpowercircuit1
O5Failsafeoutputfor
statusofpowercircuit1
TO/T1Testpulseoutput
0/1