Recovery flowchart (1-1)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1)]
RST MASK 12 (Light blue)
Recovery flowchart (1-2)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) / Recovery flowchart (1-1)]
RST MASK 10 (Pink)
Display RST MASK 10 (Pink). / [MKS S60]
Replacement of abnormal circuits or 
re-replacement of the panel required
No
Ye s
Set VOL OFFSET to the current setting value plus 112. / [VOF ***]
Gradually increase the VOL OFFSET value until disappear the 
discharge (lit cell).
The VOL OFFSET value must be 133 or less.
Current VOL OFFSET > 133?
[To the Recovery flowchart (1-2)]
Display RST MASK 02 (Red). / [MKS S52]
Replacement of abnormal circuits or 
re-replacement of the panel required
Replacement of abnormal circuits or 
re-replacement of the panel required
No
Ye s
Gradually increase the VOL OFFSET value until disappear the 
discharge (lit cell).
The VOL OFFSET value must be 133 or less.
No
Ye s
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
A
Current VOL OFFSET > 133?