Recovery flowchart (1-3)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) ]
Display RST MASK 03 (Green). / [MKS S53]
Set VOL OFFSET to the current setting value minus 48. / [VOF ***]
[To the Recovery flowchart (1-4)]
Display RST MASK 03 (Green). / [MKS S53]
Determine the current VOL OFFSET setting value as the final value.
Replacement of abnormal circuits or 
re-replacement of the panel required
Replacement of abnormal circuits or 
re-replacement of the panel required
No
Ye s
Gradually decrease the VOL OFFSET value until disappear the 
discharge (dead cell).
The VOL OFFSET value must be 117 or greater.
Current VOL OFFSET < 117?
No
Ye s
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
[To the Main flowchart (2)]
A
RST MASK 02 (Red)