K i t M a n u a l f o r P i p i s t r e l S i n u s a n d V i r u s A i r c r a f t
Determining the flaperon's moment:
Measuring the turn moment of the flaperon is done by setting it up on a special stand and
measuring the mass. The stand should hold the flaperon level and allow it to rotate on its
hinges freely.
First place the flaperon on the stand, level it and place a scale under the end which is
closest to the fuselage. Our factory made flaperons typically have a reading of
approximately 600 – 700 grams. If you don't get this reading add or remove
counterbalances accordingly.
Now assemble the flaperon to the wing using a decent amount of grease on the pins. Be
sure to use a magnet to get the washer and nut onto the end securing pin. Then tighten
http://www.pipistrel.si © Pipistrel Release March 2009 © Page 219 of 267