OPERATION & MAINTENANCE MANUAL TMS2000/3000
TMS Operations and Maintenance Manual.docx February 12, 2018
PAGE 39
User Name User-Defined Tank Name: A 6-character alphanumeric name entered via TMSComm. Note that
this is a context sensitive setting that only appears if the Tank Name is set for User
Entry Type: select list
Range Limits: 6-character alphanumeric. Must be entered via TMSComm.
Default/Initialized value: Prduct
tank id Tank ID Number: A unique two-digit numeric ID number assigned to the Tank Channel that is
recorded in all reports and tank printouts.
Entry Type: 2-digit numeric
Range Limits: 01-99
Default/Initialized value: 2-digit number corresponding to Tank Channel Number.
i.e. Tank ID 01 for Tank Channel 1, Tank ID 12 for Tank Channel 12
VOL Mode Volume Mode: Toggles between support for small to medium sized tanks (less than 1 million
gallons/liters) and support for large tanks (1 million gallons/liters and higher).
Entry Type: select list
Range Limits: by 1: Supports tanks less than 1 million gallons/liters. Displayed volume rounded
off to the nearest 1 gallon/liter
by 10: Supports tanks 1 million gallons/liters and higher. Displayed volume
rounded off to the nearest 10 gallons/liters. Note: All volume settings for a Tank
Channel configured with a Volume Mode “by 10” must be divided by 10 from the
actual value. i.e. a 2 million gallon/liter tank would have the Tank Capacity
entered as 200,000 gallon/liter
Default/Initialized value: By 1
Prod type Product Type: The Product Type selected corresponds to a predefined thermal coefficient of
expansion value for the named liquid. This is used to calculate the Net (Temperature-
Compensated) Volume as well as for performing In-Tank Leak Tests.
Entry Type: select list
Range Limits: See below table
Default/Initialized value: 87 oct
Note: For products not listed - Consult Factory