MAN. PS 254 EN – Ind. 2 51
REF DESIGNATION MAX. MIN. OUTPUT INCREMENT
DEFAULT
VALUE
Gas
T10 Pre-gas time 320 1 s 1 5
T11 Post-gas time 320 1 s 1
10
15
Current
I21 Prefusion current
200
100
2A 1 90
T21 Prefusion time 30 0,1 S 0,1 3
I22 Pulse current
200
100
2A 1 90
T22 Pulse time 9999 10 Ms 1 100
I23 Background current
200
100
2A 1 45
T23 Background time 9999 10 Ms 1 100
N20 Downslope 9999 1 D 1 365
T25 Downslope time 60 1 S 1 5
Rotation
R30
Welding head
reference
See pages 35 to 39
V32 Rotation speed (high) 999
50
then 0
/M 1 70
V33 Rotation speed (base) 999
50
then 0
/M 1 50
Wire
T40 Delay for wire start 40 0 S 1 3
V42 Wire feed speed (high) 999
50
then 0
/M 1 200
V43
Wire feed speed
(base)
999
50
then 0
/M 1 200
N40 Wire stop 9999 1 D 1 360