Reg. No. Register Name Units Range
1437 Reserved
1438 Reserved
1439 Maximum Real Power, Phase A kW/Scale Factor E 0 to ±32,767
1440 Maximum Real Power, Phase B kW/Scale Factor E 0 to ±32,767
1441 Maximum Real Power, Phase C kW/Scale Factor E 0 to ±32,767
1442 Maximum Real Power, Total kW/Scale Factor E 0 to ±32,767
1443 Maximum Reactive Power, Phase A kVAr/Scale Factor E 0 to ±32,767
1444 Maximum Reactive Power, Phase B kVAr/Scale Factor E 0 to ±32,767
1445 Maximum Reactive Power, Phase C kVAr/Scale Factor E 0 to ±32,767
1446 Maximum Reactive Power, Total kVAr/Scale Factor E 0 to ±32,767
1447 Maximum Apparent Power, Phase A kVA/Scale Factor E 0 to ±32,767
1448 Maximum Apparent Power, Phase B kVA/Scale Factor E 0 to ±32,767
1449 Maximum Apparent Power, Phase C kVA/Scale Factor E 0 to ±32,767
1450 Maximum Apparent Power, Total kVA/Scale Factor E 0 to ±32,767
1451 Maximum THD/thd Current, Phase A Percent in 10ths 0 to 10,000
1452 Maximum THD/thd Current, Phase B Percent in 10ths 0 to 10,000
1453 Maximum THD/thd Current, Phase C Percent in 10ths 0 to 10,000
1454 Reserved
1455 Maximum THD/thd Voltage, Phase A Percent in 10ths 0 to 10,000
1456 Maximum THD/thd Voltage, Phase B Percent in 10ths 0 to 10,000
1457 Maximum THD/thd Voltage, Phase C Percent in 10ths 0 to 10,000
1458 Reserved
1459 Reserved
1600– Unused
1616
These registers can be used with POWERLOGIC, Modbus, or Jbus protocols. Although POWERLOGIC
and Jbus protocols use a zero-based register addressing convention and Modbus uses a one-based
register addressing convention, the power meter, when configured for Modbus communications,
automatically compensates
for the Modbus offset of one. Regard all registers as holding registers where a
30,000 or 40,000 offset can be used (e.g., Current, Phase A = 31,003 or 41,003).
PM-650 only.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PowerLogic PM-620 and is the answer not in the manual?

PowerLogic PM-620 Specifications

General IconGeneral
BrandPowerLogic
ModelPM-620
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals