Page 327
6 Loosen the adjustment bolt for the step up pulley until tension has
been removed from the input pulley belt and it can be removed from
the pulleys.
Figure 274: Step Up Pulley
Gas Shock Removal
7 Release tension from the top of the gas shock by pushing a # 1 flat
top screw driver in the slot under the tension clip. Do not
completely remove the retaining clip as it is difficult to
reinstall.
Tip: If the incline motor is jammed at full elevation, remove the lower retaining
clip to facilitate the gas shock removal.
8 Using another flat head screw driver as a pry bar, place the screw
driver head between the frame and the top of the gas shock and pry
the shock off the upper mounting stud.
9 Rotate the gas shock down and out of the way of the incline motor.