Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
14. IGNITION CONTROL FLASHES
(Figure 1)
NOTE: This control will lock-out the igniter after four failed attempts at ignition. The control can be reset by
opening loading door, waiting 1 minute, then closing loading door. If door is closed before waiting 1 minute, the
control will re-enter lockout. The red light will flash a Flash Code when the control is in the lock-out mode. The
light will flash on for 1/4 second then off for 1/4 second for each number. The pause between flash codes is 2
seconds. These flashes are caused by the control’s diagnostic test and can be interpreted by reading the following:
FLASH CODE POSSIBLE CAUSE TO CORRECT
Constant Light Internal failure. Reset dryer. If condition persists, then
replace control.
One Flash Air in gas line. Purge air from gas line.
Sensor coated with Aluminum Oxide. Wipe sensor clean or replace sensor if
necessary.
Incorrect gas pressure. Check for correct gas pressure. If gas
pressure is incorrect, then contact local gas
company.
Gas shut-off valve closed. Open gas shut-off valve.
Four Flashes Internal failure. Reset dryer. If condition persists, then
replace control.
Loose or disconnected wiring. Check all wiring leading to, or coming from,
the control module for secure connections.
Open Igniter/igniter sensing circuit/voltage
measurement circuit.
Check igniter and all circuits, replace if
necessary.
Five Flashes Loose or disconnected wiring. Check all wiring leading to, or coming from,
the control module for secure connections.
Inoperative gas valve. Check gas valve and replace if necessary.
Inoperative sensor. Replace sensor/igniter.
Six Flashes Loose or disconnected wiring. Check all wiring leading to, or coming from,
the control module for secure connections.
Incorrect wiring. Check wiring diagram and make sure dryer
is wired correctly.
Incorrect polarity. Contact a professional electrician to check
the polarity, and correct any problems.
(continued)