Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
45. HEATING ELEMENT (Electric Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to Figure 7.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to Figure 37.
c. Disconnect wires from element and plate. Refer
to Figure 43.
d. Remove two screws holding element and plate
to heater box and remove element and plate out
through front of dryer. Refer to Figure 43.
NOTE: When reassembling, be sure all wire
connectors are tight on element terminals, thermal
fuse and limit thermostat.
ELECTRIC MODELS
SILICON CARBIDE
SILICON NITRIDE
Figure 43
HEATER
ASSEMBLY
HEATER WIRE
CONNECTIONS
LIMIT
THERMOSTAT
THERMAL
FUSE
SCREW
D398SE1A
LIMIT
THERMOSTAT
BURNER
TUBE
SCREW
BURNER TUBE
SCREW
GAS VALVE
HANDLE
(Shown in Open
Position)
BASE
BURNER
HOUSING
D399SE1A
WR
LIMIT
THERMOSTAT
THERMOSTAT
BURNER TUBE
SCREW
GAS VALVE
HANDLE
(Shown in
Open
Position)
BASE
BURNER
HOUSING
D363SE1B
BURNER
TUBE
SCREW