Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
56. TERMINAL BLOCK OR POWER CORD
a. Terminal Block:
(1) While supporting the access panel, remove
two screws from bottom edge of access
panel. Refer to Figure 7.
(2) Gently lower the access panel to disengage
locators from bottom edge of front panel.
Refer to Figure 37.
(3) Remove two screws holding bottom tabson
front panel to dryer side panels. Refer to
Figure 37. Swing bottom of front panel
away from dryer far enough to disengage
hold-down clips and locators from cabinet
top.
(4) Disconnect wires from door switch. Refer
to Figure 36.
NOTE: Refer to wiring diagram when rewiring
switch.
(5) Remove two cabinet top hold-down
screws. Refer to Figure 28.
(6) Lift cabinet top to a vertical position by
hinging it on the rear hold-down brackets.
Refer to Figure 29.
NOTE: When servicing, cabinet top may be raised
and hinged on the rear hold-down brackets, or
supported against wall behind the dryer.
(7) Remove all wires from terminal block.
NOTE: Refer to wiring diagram when rewiring
terminal block.
(8) Remove screw holding terminal block to
rear bulkhead. Refer to Figure 61.
Figure 61
CABINET
TOP
TERMINAL BLOCK
ATTACHING
SCREW
TERMINAL
BLOCK
D406SE3A