EasyManua.ls Logo

Primus DAM 9 - 24 Electronic Control

Primus DAM 9
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 516514
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
24. ELECTRONIC CONTROL
(Figure 11)
IMPORTANT: Due to the sensitivity of the
electronic control, careful handling is required. As a
precautionary measure, we recommend using a
ground wrist strap when handling the electronic
control. Wrist strap, cord and alligator clips are
designed to carry away any electrostatic charge
from your body and to direct charge to an available
ground. By using this static protection device,
potential electrostatic discharge problems
associated with handling of electronic control will
be minimized. Always handle electronic control by
its metal edges. If a wrist strap is not available,
touch dryer while it is plugged in before handling
control to dissipate any charge.
NOTE: New control is supplied in special anti-static
packaging material. While holding control by its
metal edges, remove control from packaging
material.
a. Remove two control panel attaching screws.
Lay control panel assembly face down on
protective padding.
b. Press in on locking tabs and unplug harness
disconnect blocks from backside of electronic
control assembly.
NOTE: DO NOT pull on wires. Instead, hold board
near appropriate disconnect block and unplug by
pulling in disconnect block.
c. Remove four screws holding electronic
controls assembly to backside of control panel.
d. Place the old control in the anti-static
packaging material that the new control was
supplied in.
e. While holding new control by its metal edges,
carefully peel off protective plastic coating
from front side of control. Then place control in
opening of control panel and fasten control
down with four screws.
f. Follow wiring diagram and reconnect wires to
new control.
IMPORTANT: It is important to take care when
handling the original control. It must be carefully
placed in the packaging material which was
removed from new control. If control is not
wrapped properly, warranty credit will not be
issued.

Table of Contents