8.3 Status display Warning
The display flashes. An explanation of the warning is displayed on
the bottom line. In this state, the control module delta
®
is still func‐
tional.
Photo Warning Description
!
Control module
A warning from the control module delta
®
has been detected
n Error with the feedforward control (control module delta
®
still
operates)
n Overflow of the control module output value (control module
delta
®
still operates)
n The control module is located in basic load control
checkout time,
A warning from the control module delta
®
has been detected
n Checkout time has elapsed (control module delta
®
still with
basic load)
!
Limit The limit value has been exceeded / undershot
n The control module delta
®
is located in basic load control
!
Calibration A calibration error has been detected
When an error has been detected then the calibration data will not
be accepted. Operation is continued with the old data. This affects
the calibration for the current interface and the sensors. If a
warning is displayed during a sensor calibration, this could indicate
a sensor error.
8.4
Warnings control module delta
®
Warning Description
Communication A continuous communication error has been determined
Software / data
n Configuration values are inconsistent
n Communication error (unknown reply, wrong checksum)
Controllers
n Limit value undershot / exceeded
n Checkout time elapsed
Troubleshooting
44

Table of Contents

Other manuals for ProMinent delta

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent delta and is the answer not in the manual?

ProMinent delta Specifications

General IconGeneral
Stroke ratemax. 180 strokes/min
TypeDiaphragm metering pump
MaterialsPVDF, PTFE, stainless steel
Protection classIP 65
Diaphragm materialPTFE
DriveSolenoid
Power supply230 V, 50/60 Hz

Related product manuals