NOTICE!
Correct sensor operation / Run-in time
Damage to the product or its surroundings
Correct measuring and dosing is only possible if
the sensor is working perfectly
It is imperative that the run-in times of the sensors
are adhered to
The run-in times should be allowed for when plan‐
ning initial operation
It may take a whole working day to run-in the
sensor
Please read the operating instructions for the
sensor
NOTICE!
Correct sensor operation
Damage to the product or its surroundings
Correct measuring and dosing is only possible if
the sensor is working perfectly
Check and calibrate the sensor regularly
NOTICE!
Compensation of control deviations
Damage to the product or its surroundings
This controller cannot be used in control circuits
which require rapid compensation (< 30 s)
2.2
Specific safety instructions for the control module delta
®
WARNING!
Emergency stop switch
Possible consequence: Fatal or very serious injuries
An emergency stop switch on the complete system.
This should enable the complete system to be
switched off in event of an emergency in such a way
that the complete system is stopped in a safe condi‐
tion.
WARNING!
Hazardous substances
Danger resulting from contact, breathing in or other
contaminations with / from substances or media
Observe the safety data sheet of the substances /
media used
The system operator must ensure that these safety
data sheets are available and that they are kept up
to date
Safety and responsibility
9

Table of Contents

Other manuals for ProMinent delta

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent delta and is the answer not in the manual?

ProMinent delta Specifications

General IconGeneral
Stroke ratemax. 180 strokes/min
TypeDiaphragm metering pump
MaterialsPVDF, PTFE, stainless steel
Protection classIP 65
Diaphragm materialPTFE
DriveSolenoid
Power supply230 V, 50/60 Hz