normal HV1 HV2 HV3
L
t
P_G_0075_SW
Fig. 34: Suction stroke metering profiles with stroke L and time t
Normal Normal suction stroke
HV1 Suction stroke for viscous feed chemical
HV2 Suction stroke for average viscosity feed chemical
HV3 Suction stroke for high-viscosity feed chemical
–
Slowing down the suction stroke leads to a lower stroke
rate and thus to a lower capacity.
‘Suction stroke’
setting Maximum stroke rate
Strokes/min
Normal 200
HV1 160
HV2 120
HV3 80
11.2.4.3
‘Pressure Stage’
‘Menu / Information
è
Settings
è
Metering
è
Pressure stage
è
...’
You can use the programmable function
‘Pressure stage’
to reduce the
nominal pressure of the pump, thereby minimising the risk of lines rup‐
turing.
The switch-off pressure of the permanently active overpressure monitoring
falls at the same time as the pressure stage - see .
Nominal pressures depending on the size of the liquid ends and the pressure stages
Pressure
stage /
4 7 10 16 20 25
Size of liquid
end
1602 X X X X - -
2002 X X X - X -
1604 X X X X - -
2504 X X X - - X
Set Up /
‘Menu’
53