N93-582-01 Issue 1 NH Page 7 of 42 © Protec Fire Detection plc 2015
2.0 List of Device Types Compatible with the Digilite® DL500
Table 2.0 gives a list of loop devices that are compatible with the Digilite® DL500 , along with a brief
description of each device. For full details of the range please contact Protec.
Table 2.0.
Digilite® Loop Device
Panel Type
Text
Brief Description
Self Contained Bulkhead S_CONT
An 8W non LED bulkhead fitting that is generally
powered by a local 2 cell battery.
Conversion Module CONV
A module which is incorporated into third party
luminaires in order to permit them to be automatically
tested. Available in 2,3,4,5 and 6 cell variants.
Powerflood Luminaire PFLOOD
A twin spot high intensity non-maintained unit designed
for high bay wide area coverage.
LED Driver LEDDRV
A self contained bulkhead luminaire using LED
technology which can be maintained or non-
maintained.
LED Ballast LEDBAL
A driver for higher power LED down lighters, which can
be maintained or non-maintained.
Current Monitor Module CM_INT
A range of modules which monitor and report back the
mains current drawn by a fitting. Available in various
current ratings and in AC only and AC/DC models.
Loop Interfaces Designed for Central Systems
Static Inverter Control Module STAT_CT
A module that fits within and interfaces to a Central
Battery or Static Inverter power source. The interface
can put the central system into 'test' mode and reports
back faults.
Static Inverter Loop Module STAT_LP
A module that fits within each luminaire connected to a
centrally supplied system. The module can swap the
feed to the local luminaire from a local mains supply to
the backup supply, and monitors the lamp output.
This module may also be used as a Sub Circuit
Monitoring device by using appropriate programming in
the Digilite® DL500.
Local Fuse Failure Relay LFFR
A module that can control a contactor and is used,
under panel control, to fail local mains circuits in order
to put circuits of luminaires into test mode.
LDR Slave LDR_S
A legacy module which interfaces to an LDR and is
used to monitor slave lamps on a central system.
110V Electronic Ballast ELEC_B
A 110V 8W bulkhead fitting designed to connect to
110V central systems.