Chapter 1 Introduction
PA-6225 SERIES USER MANUAL
Page 9
120W
Power Supply: 72 ~ 120Watt power adapter
Power Consumption (AC):
System
Status
CPU/
HDD/
Memory
VFD
Printer
COM & USB
Ports to supply
power of Rear I/O
Consumption
OFF
Off
without
2W
IDLE
Turns on, but
not to execute
extra AP
Runs
new
ticker
Standby
19.8W
Working
(without
printer)
100% loading
of burn-in test
25.6W
Working
(with
printer)
DC24V
1.4A dummy
load
59.1W
Full Loading
USB dummy load
500mA x4
68.9W
Certificate: CE, CE-LVD, FCC
Type
Standard
Description
EMI
EN 55022 Class A
-
EMS
EN 55024
-
IEC 61000-4-2
ESD
8kV air discharge
4kV contact discharge
IEC 61000-4-3
RS
80~1000MHz, 3V/m, 80% AM(1kHz)
IEC 61000-4-4
EFT
AC Power Port: 1kV
DC Power Port: 0.5kV
Signal Ports & Telecommunication
Ports: 0.5kV
IEC 61000-4-5
Surge
AC Power Port:
Line to line: 1kV
Line to earth(GND): 2kV
DC Power Port:
Line to earth(GND): 0.5kV
Signal and Telecommunication Port:
Line to GND: 1kV
IEC 61000-4-6
CS
0.15~80MHz, 3Vrms, 80% AM, 1kHz
IEC 61000-4-8
PFMF
50Hz, 1A/m
IEC 61000-4-11
Voltage Dips
> 95% reduction for 0.5 periods
30% reduction for 25 periods
Voltage Interruptions
> 95% reduction for 250 periods

Table of Contents