ULTRA 3 INSTRUCTION MANUAL
50
PARAMETER
DEFAULT
DESCRIPTION
P213 / P214
Relay 1 ON/OFF
setpoints
Factory preset as a % to
appropriate level according
to the span already
entered. See tables below
Either Alarm or Level control.
Depends on application.
P223 / P224
Relay 2 ON/OFF
setpoints
Factory preset as a % to
appropriate level according
to the span already
entered. See tables below
Either Alarm or Level control.
Depends on application.
P233 / P234
Relay 3 ON/OFF
setpoints
Factory preset as a % to
appropriate level according
to the span already
entered. See tables below
Either Alarm or Level control.
Depends on application.
P830 mA Out Range
2 = 4 to 20mA
Determines the mA output
range.
0 = Off, 1 = 0 to 20mA, 2 = 4
to 20mA, 3 = 20 to 0mA, 4 =
20 to 4mA.
P870 Fill Damping
10m/min
Rate of maximum fill rate (set
above the actual fill rate of the
vessel).
P871 Empty
Damping
10m/min
Rate of maximum empty rate
(set above the actual rate of
the vessel).