Matrix 424/832/832+ LCD Programming Manual
Page 10 RINS916-6
4. SYSTEM OPTIONS
4.1 System Options 1 (Function 200)
Press .
This starts the function
SYSTEM OPTIONS 1
OPTION 1 OFF
The current system options are displayed.
Select any option by using the and
keys, or use the – keys to select that
option directly.
Press to toggle the option
ON
or
OFF
.
Press to accept the options.
There are 8 options
SYSTEM OPTIONS 1
OPTION 8 OFF
SYSTEM OPTIONS 1
OPTION 7 OFF
SYSTEM OPTIONS 1
OPTION 6 OFF
SYSTEM OPTIONS 1
OPTION 5 OFF
SYSTEM OPTIONS 1
OPTION 4 OFF
SYSTEM OPTIONS 1
OPTION 3 OFF
SYSTEM OPTIONS 1
OPTION 2 ON
SYSTEM OPTIONS 1
OPTION 1 OFF
№ OPTION OFF OPTION ON
1 AC Fail Warning Enabled AC Fail Warning Disabled
2 Battery Monitoring Disabled Battery Monitoring Enabled
3 Link Only NVM Reset Engineer Code and Link NVM Reset
4 No Limit Log & Event Reporting Limit Log & Event Reporting (16 Events)
5 Telephone Line Fail Fault Indication Only Telephone Line Fail Alarm & Fault Indication
6 Global Tamper 0V Removed Global Tamper 0V Applied
7 50Hz AC Frequency 60Hz AC Frequency
8 AC Derived Real Time Clock Quartz Derived Real Time Clock
Shaded = Default