Matrix 424/832/832+ LCD Programming Manual
Page 32 RINS916-6
11. SYSTEM TIMERS
11.1 Bell Time (Function 500)
Press .
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current bell time is displayed.
Example shows 04
(minutes or seconds)
ENTER BELL TIME
04
Enter 2 digits for the new time (00 – 99).
Example shows 30
(minutes or seconds)
ENTER BELL TIME
30
Press to accept the changes.
NOTE: Default is 4 minutes.
11.2 Bell Time Delay (Function 501)
Press .
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current bell time delay is displayed.
Example shows 00
minutes
ENTER BELL DELAY
00
Enter 2 digits for the new delay (00 – 99).
Example shows 02
minutes
ENTER BELL DELAY
02
Press to accept the changes.
NOTE: Default is 0 minutes.
NOTE – Italy: Bell Delay MUST be set to 0 to comply with CEI79.
11.3 Entry Time (Function 502)
Press .
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current entry time is displayed.
Example shows 20
seconds
ENTER ENTRY TIME
20
Enter 2 digits for the new time (00 – 99).
Example shows 30
seconds
ENTER ENTRY TIME
30
Press to accept the changes.
NOTE: Default is 20 seconds.