Matrix 424/832/832+ LCD Programming Manual
Page 50 RINS916-6
16.1.1 Event Log Interpretation Table
DESCRIPTION
/
MAIN ENTRY
ADDITIONAL DATA
Beginning of the log
DISPLAY LOG
▼
End of the log
DISPLAY LOG
▲
ALARMS & TAMPERS
Entry time expired.
The number refers to the zone
TIME & DATE
►ENTRY / EXIT
ZONE NAME
►01-32
Burglary on zone, number signifies zone
TIME AND DATE
►ALARM
ZONE NAME
►01-32
Tamper on zone, number signifies zone
TIME AND DATE
►ZONE TAMPER
ZONE NAME
►01-32
PA zone activated, number signifies zone
TIME AND DATE
►PERSONAL ATK
►01-32
Fire zone activated, number signifies zone
TIME AND DATE
►FIRE ALARM
►01-32
2-wire Fire detector input activated (PGM4)
TIME AND DATE
►FIRE ALARM
►99
Medical zone activated, number signifies zone
TIME AND DATE
►MEDICAL ALARM
►01-32
PA alarm activated from a keypad
TIME AND DATE
►PERSONAL ATTACK
►00
Fire alarm activated from a keypad
TIME AND DATE
►FIRE ALARM
►00
Medical alarm activated from a keypad
TIME AND DATE
►MEDICAL ALARM
►00
Telephone line fail alarm
TIME AND DATE
►TEL LINE ALARM
►
Global tamper loop broken
TIME AND DATE
►TAMPER
►01
Bell tamper loop broken
TIME AND DATE
►TAMPER
►02
Plug on zone expander board not present
TIME AND DATE
►TAMPER
►03
2-wire Fire detector input tamper (PGM4)
TIME AND DATE
►TAMPER
►05
Remote device missing caused tamper
TIME AND DATE
►TAMPER
►06
Keypress tamper – 16 wrong keypress
in armed mode
TIME AND DATE
►TAMPER
►08
Remote device case tamper
TIME AND DATE
►TAMPER
►09
Remote device front tamper activation,
01 – 82 = Type/ID
TIME AND DATE
►DEVICE TAMPER
DEVICE 01-82
►01-82 01

Table of Contents