Matrix 424/832/832+ LCD Programming Manual
Page 34 RINS916-6
11.7 Inactivity Auto Arm (Function 506)
Press .
ENTER PARTITION
_
Enter 1 digit for the partition (1 – 4).
Example shows Partition
1
This display is quickly
followed by the next
ENTER PARTITION
_1
The current time is displayed.
Example shows
Inactivity Auto Arm
disabled (0000)
ENTER INACT TIME
00
Enter 2 digits for the new inactivity time (00 –
99).
The number entered x 10 = time in minutes.
NOTE: The time is automatically accepte
after entering the 2
nd
digit.
Example shows 2 hours
(12 x 10 = 120 minutes)
ENTER INACT TIME
12
NOTE: Default is 00 (Inactivity Auto Arm disabled).
11.8 AC Fail Warning Delay (Function 507)
Press .
The current delay time
is displayed
ENTER DELAY TIME
10
Enter 2 digits for the new delay time (00 – 99).
Example shows 20
minutes
ENTER DELAY TIME
20
Press to accept the changes.
NOTE: Default is 10 minutes.
11.9 Telephone Line Fail Warning Delay (Function 508)
Press .
The current delay time
is displayed
ENTER DELAY TIME
10
Enter 2 digits for the new delay time (00 – 99).
Example shows 20
minutes
ENTER DELAY TIME
20
Press to accept the changes.
NOTE: Default is 1 minute.
11.10 Seconds in Last Minute of Day (Function 509)
Press .
The current number of
seconds is displayed
ENTER SECONDS
60
Enter 2 digits for the new delay time (00 – 99).
Example shows 65
seconds
ENTER SECONDS
65
Press to accept the changes.
NOTE: Default is 60 seconds.