Communication Protocol CubiScan 125 Command Set
CubiScan 125 Service Manual 71
Scale Calibration Code Descriptions:
SA01 Clear the CubiScan
SA02 Place Test Weight in Corner
SA03 Scale Calibration Complete
Test
This command causes the CubiScan 125 to reply with an error code. A response of TA00 means
that the CubiScan 125 is ready and responding to transmissions from the host. If the host receives
no response from the control unit after sending this command, an error condition exists in the
communications between the host and control.
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Self Test Command Alpha (T) 54h
31End of Text Control(ETX) 03h
4 1 Carriage Return Control (CR) 0Dh
51Line Feed Control(LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Self Test Command Alpha (T) 54h
3 1 Acknowledge Alpha (A) 41h
4 2 Identifier Numeric (00-99)
61End of Text Control(ETX) 03h
7 1 Carriage Return Control (CR) 0Dh
81Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Self Test Command Alpha (T) 54h
31Neg. Acknowledge Alpha (N) 4Eh
41End of Text Control(ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
61Line Feed Control(LF) 0Ah

Table of Contents