Communication Protocol TCP/IP Communications Setup Command Set
CubiScan 125 Service Manual 79
Read IP Address
This command is used to read the current IP address setting from the CubiScan 125.
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
3 1 IP Address Command Alpha (I) 49h
4 1 Acknowledge Alpha (A) 41h
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
71Line Feed Control(LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
3 1 IP Address Command Alpha (I) 49h
4 1 Neg. Acknowledge Alpha (N) 4Eh
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
71Line Feed Control(LF) 0Ah
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (~) 7Eh
3 1 IP Address Command Alpha (I) 49h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (~) 7Eh
3 1 IP Address Command Alpha (I) 49h
4 1 Acknowledge Alpha (A) 41h
5
7-15
or n
IP Address Alpha
(0.0.0.0) to
(255.255.255.255
)
5+n 1 End of Text Control (ETX) 03h
Pos Len Description Type Range ASCII