EasyManuals Logo

Ramsey Electronics COM3010 User Manual

Ramsey Electronics COM3010
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
90
DETAILED INFORMATION
6.50.05 GET Commands
Major
Comma
nd
Sub-command Low High Returns Description
Bottom Meters
GET RFCOUNT 0 1200.000000M
Hz
####.#####
#MHz
Get current RF frequency
count specified by the
current counter mode
(see counter mode lists)
GET AFCOUNT 0 6000 ####.#kHz
Get current AF count, only
if AF counter is selected
as one of the meters
GET FMDEV 0 +/-7kHz +#.##kHz/-
#.##kHz
Get current FM deviation
(numerically)
GET DELTAF +/-
####.#####
#MHz
Get frequency error from
current receive frequency
(see counter mode lists)
GET DBSINAD,SINA
D,SIN
0dB 40dB ##.#dB
Get dB SINAD (see valid
meter mode lists)
GET AM% 0 100% ###%
Get AM percent reading if
in AM receive mode and
proper meter is selected.
Top Meters
GET POWER 0 100W ###W
Get Measured power
GET BAT 10V 16V ##.#V
Get Battery Voltage
GET RSSI -100dBm -30dBm ##dBm
Get receiver RSSI
GET SQUELCH O (OPEN) C (CLOSED) O/C
Get squelch state
Property of Ramsey Electronics, Inc.
Do not reproduce or distribute.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ramsey Electronics COM3010 and is the answer not in the manual?

Ramsey Electronics COM3010 Specifications

General IconGeneral
BrandRamsey Electronics
ModelCOM3010
CategoryMonitor
LanguageEnglish

Related product manuals