Generator Side
SET GF ###.#####
#MHz
0.100000M
Hz
1000.000000
MHz
OK/BAD
Set Generator
frequency
SET GEN,GENSTAT
E
ON/OFF ON OFF OK/BAD
Sets the Generator
State. By default
when entering the
serial mode, this is
set to ON.
SET GL,LVL,LEVEL -###.#dBm -120 0 OK/BAD
Set Generator Level
SET MEXT ON/OFF ON OFF OK/BAD
Set Mod External
SET MINT ON/OFF ON OFF OK/BAD
Set Mod Internal
SET MCTS ON/OFF ON OFF OK/BAD
Set Mod CTS
SET MDCS ON/OFF ON OFF OK/BAD
Set Mod DCS
SET MALL OFF N/A OFF OK/BAD
Turn off all
modulations
SET GFM
Set Generator in FM
mode
SET GAM
Set generator in AM
mode
SET EXTDEV ##.####kHz 0Hz 75.0000kHz OK/BAD
Set FM modulation
deviation
SET EXT% ##% 0% 75% OK/BAD
Set AM modulation
percent
SET INTTONE #.####kHz 0.1Hz 3.0000kHz OK/BAD
Set FM Tone
frequency
SET INTDEV ##.####kHz 0Hz 75kHz OK/BAD
Set FM modulation
deviation
SET INT% ##% 0% 75% OK/BAD
Set AM modulation
percent
SET AGC # 1 4 OK/BAD
Set Internal
Modulation AGC
Mode (See valid AGC
mode list)
SET CTS ###.#Hz 0 999.9 OK/BAD
Set CTS tone in Hz
SET CTSDEV #.####kHz 0.1Hz 2.000kHz OK/BAD
Set CTS Deviation
SET DCS ### See valid
lists.
OK/BAD
Set DCS code
SET DCSDEV #.####kHz 0.1Hz 2.000kHz OK/BAD
Set DCS Deviation
6.50.03 SET Commands
Property of Ramsey Electronics, Inc.
Do not reproduce or distribute.

Table of Contents