11
c) Depress and hold . The previous 3 settings that were selected will
be displayed in the DATA display. Verify the selections made are correct
before proceeding to the next step. If an error is noted, place POWER switch
OFF, depress and hold
, place POWER switch to ON, and repeat steps
1-3.
NOTE: For the remainder of the Console programming the
and keys will
be used advance through the various selections.
4) Enter the following values in
. Depress to advance through the BLAST
CAL menu.
DISPLAY SCREENS
LIQ DATA PROCEDURE
CAL bL-r 0 Enter the desired Blast Rate
(gal/mile) [lit/km].
CAL bL-S 0 Enter the desired Blast Time (seconds).
5) Enter an initial value of "200" in
. The actual SPEED CAL number
will be obtained after initial programming is completed. Refer to section
"CALCULATING SPEED CAL" for more instructions.
6) Enter the calibration number from flow meter tag in .
7) Enter VALVE CAL number based on selected control valve type in
. C-P
(53), C-Sd (2123), C-F (743), C-FC (743) refer to Appendix 2 page 29 for
information to adjust this value if necessary.
8) Enter the following values in
. Depress the and keys to
advance through rates 1-10 ("r-01" through "r-10").
DISPLAY SCREENS
LIQ DATA PROCEDURE
CAL r-01 0 Enter the desired application rate
(gal/mile) [lit/km].
YOU HAVE NOW COMPLETED INITIAL CONSOLE PROGRAMMING.
The flashing "CAL" will now extinguish. If not, repeat procedure starting at Step 4.