13. AUTOMATIC RATE +/-
This feature allows an increment to be set at which flow may be increased or
decreased while in automatic operation (rates 1-10). To select RATE +/- depress
until the right DATA display flashes. To enter a value depress ,
increment value, and
. When using this feature the preprogrammed
application rates will be changed accordingly.
EXAMPLE: If application rate is to change by "10":
Enter a value of 10 for RATE +/-. When in RATES 1-10, each time the MANUAL
INC/DEC switch is positioned to INC, the RATE will increase by "10".
Likewise, when positioned to DEC, the RATE will decrease by "10".
14. MANUAL MODE LOCK OUT
If the key switch is in the vertical position (operate mode) and the Manual
Control is off (see DATA MENU); the manual position (M) of the RATE knob will
only function under two (2) conditions:
1) No speed (typical scenario to unload truck).
2) No flow signal.
With the RATE knob placed to the manual position (M) the Console will default
to RATE 1 unless the above conditions exist. If the key is in the horizontal
position (program mode); OR the key is vertical and the manual control
is ON (see DATA MENU); the manual position (M)is active for all conditions. Using
the MANUAL INC/DEC switch will increase or decrease your application rate.