OTHER CONSOLE FEATURES
1. VOL/TANK
This feature allows the operator to monitor the amount of liquid remaining in
the tank. Enter the volume of liquid (gal)[lit] in the tank in
and the
console will decrease the volume as the liquid is being applied. This volume
must be entered each time tank is filled.
2. LOW TANK ALARM
This feature will sound the alarm when the liquid volume drops below an entered
value. If the liquid volume falls below the low tank value entered, the alarm
will sound 8 beeps every 15 seconds and LIQ display screen will flash "LEul".
The alarm will stop when a value equal to or greater than the Low Tank Alarm value
is entered into VOL/TANK, or the MASTER switch is turned OFF. Entering "0"
into Low Tank Alarm disables the alarm.
a) Depress
until the right DATA display flashes.
b) To enter a value, depress
, LOW TANK ALARM value, and .
NOTE: Go to DATA MENU to silence audible alarm.
3. LOW TANK LEVEL SHUT-OFF
This feature automatically closes the lane valves when the tank volume reaches
the Low Tank Alarm. The valves will automtically open when a value greater than
the Low Tank Alarm value is entered into VOL/TANK. Refer to DATA MENU
MISCELLANEOUS SCREENS for procedure to use this feature.
4. ZERO SPEED SHUT-OFF
This feature automatically closes the lane valves when the consoles registers
zero speed. The valves will automatically open when a speed registers in the
console. Refer to DATA MENU MISCELLANEOUS SCREENS for procedure to use this
feature.