18
Low Limit Flow Alarm
Example:
1) Place RATE knob to the lowest application rate, typically this will be
RATE 1.
2) Enter a SELF TEST speed.
3) Observe the volume/minute ("FLAn").
4) Enter a lower SELF TEST speed.
5) Repeat steps 3 & 4 until the lowest acceptable spray pattern is reached.
6) Record minimum volume/minute when the spray pattern is acceptable. Enter
this value for the minimum flow ("LLAn").
Tier Enable
Example:
Main spray bar capacity - 15 (gal/min) [lit/min]
Tier 2 capacity - 30 (gal/min) [lit/min]
Tier 3 capacity - 60 (gal/min) [lit/min]
Total System capacity - 105 (gal/min) [lit/min]
Set Tier 2 Enable at 15 (gal/min)[lit/min](main spray bar)Set Tier 3 Enable
at 45 (gal/min)[lit/min](main spray bar + tier 2)Percentage tier disable
default is 10%. In this case, tier 2 would be enabled at 15.0 (gal/min)[lit/
min] and disabled at 13.5 (gal/min)[lit/min]. Tier 3 would be enabled at
45.0 (gal/min) [lit/min] and disabled at 40.5 (gal/min) [lit/min].
10. AREA/HOUR
Displays number of lane miles being covered per hour. If lane width is zero
then the area per hour value will also be zero.
11. BLAST BUTTON
1) Depressing the BLAST button will cause the system to go to the programmed Blast
Rate. The system will remain at the Blast Rate for as long as the button is
depressed plus the programmed Blast Time after the button is released. If the
BLAST button is used with zero speed the Console will assume a speed of 5 MPH
[7 Km/hr].
2) To display the number of times the BLAST feature was used, depress and hold
for 5 seconds until right DATA display flashes. To zero this total,
enter a "0".
12. CONTROL VALVE DELAY
Depress until the right DATA display flashes. The first digit,
( X 0 0 0 ), is the Control Valve delay digit. This feature allows the user to
set a delay between the time the MASTER is turned on and when the Console begins
to control the application rate. A value of 1-9 means a delay of 1-9 seconds
respectively. A value of 0 means no delay.