CHAPTER 7
80 CAN Sidekick Pro Injection for Case IH 3/4XXX Installation and Operation Manual
ALARMS
TABLE 2. Sidekick Pro Error Codes
Error Description Possible Cause Solution
Off Rate Alarm
•Difference
between actual
and target
application rates
has been greater
than the entered
value for the “Off
Rate Percent” for
more than 5
seconds
Required flow rate is out of range for the injection
pump. Calculate the volume per minute required for
the application and verify rate is within range of the
injection pump.
Low Tank Alarm
Chemical supply
tank is below the
refill threshold
level
Refill injection chemical supply tank and reset tank
level in VT display.
Flow Error Alarm
Flow obstruction
in inlet cartridges
Perform a pump calibration test. If the pump does not
calibrate properly, remove the intake cartridges and
perform pump maintenance to clear obstructions.
Chemical supply
tank is out of
chemical
Refill chemical supply tank and perform the pump
priming procedure.
Flow Error Alarm
Flow obstruction
in discharge
cartridges
Perform a pump calibration test. If the pump does not
calibrate properly, remove the discharge cartridges
and perform pump maintenance to clear obstructions.
Low Pressure
Alarm
Injection pressure
is lower than
carrier pressure
Perform a pump calibration test. If the pump does not
calibrate properly, clean the injection pump inlet and
discharge valves.
Calibrate the pump transducer.
Check lines between injection pump and in-line mixer.
Verify all hand valves are in the correct position.
Replace the pump transducer.
Maximum Vacuum
Alarm
•Clogged pump
strainer
Clean pump strainer and check for obstructions in
injection line between the pump inlet and chemical
supply tank.
•Tubing or
plumbing size
restriction
Verify the proper size of injection supply tubing is
used between the chemical supply tank and pump
inlet.
Hand Valve Closed
Check that hand valves are open and allow flow from
the tank to the injection pump inlet
Chemical too thick
Dilute product in chemical supply tank. Some
chemicals may not be applied using a direct injection
system.