CHAPTER
7
Troubleshooting: Motor Control Node LED Status Indicators 79
CHAPTER 7
TROUBLESHOOTING
MOTOR CONTROL NODE LED STATUS INDICATORS
The Sidekick Pro integrated motor control node displays the status of the injection pump with the following node
status indicators.
FIGURE 1. LED Status Indicators
TABLE 1. LED Status Indicators
LED Status Display
Logic Power
If logic power is present at the motor control node, the logic power
indicator will be on.
High Current Power
If high current power is present at the motor control node, the high
current power indicator will be on.
CAN Status
The CAN status indicator will flash once per second if the motor
control node is communicating on the CANbus. If the motor control
node cannot communicate via the CANbus, the CAN status indicator
will flash four times per second.
Flow Switch State
The flow switch indicator will flash once per revolution of the
injection pump shaft.
Flow Switch State
CAN Status
High Current Power
Logic Power