CHAPTER 6
74 CAN Sidekick Pro Injection for Case IH 3/4XXX Installation and Operation Manual
ALARMS SET-UP
This section explains how to configure the Alarm Setup screen for the sprayer or floater control system.
1. On the home screen, press the Toolbox icon . This will open the Toolbox screens.
2. Press the Alarms icon to display the Alarm Setup screen. Set the following:
Valve Cal 2
Use the Valve Cal 2
window to set the
rate change and low
rate stability
calibration. This
value is based on
injection pump size
and the PWM valve
type.
Note: If the sprayer
is equipped with
the AIM Command
PRO™ spray system,
use the same Valve
Cal 2 value as the
PWM valve type.
Press the Valve Cal 2 window to access the keypad.
Enter a valve of 5054 for 5-200 oz-min injection pumps.
Pump Size
Use the Pump Size
window to select
the correct pump
size for each tank in
a direct injection
system. The flow
output range of the
pump determines
the selection.
Note: The Pump
Size window
displays only when
a direct injection
tank is selected in
the Rate Controller
window.
Press the Pump Size window to access the pop-up options
window.
1-40 Injection Pump - An injection pump with a flow output
rate of 0.3 - 11.8 dL/min (1.0 - 40.0 US fl oz/min)
5-200 Injection Pump - An injection pump with a flow output
range of 1.5 - 59.2 dL/min (5.0 - 200.0 US fl oz/min)
Select the correct pump size for the selected rate
controller.