20 ST60+ Speed Instrument Owner’s Handbook
Fitting transducer
The ST60+ Speed instrument is supplied, with a through-hull Speed transducer.
The Speed transducer is supplied with detailed instructions for installation and
maintenance. Before attempting to install the Speed transducer, read these
instructions and the
Site requirements
for transducers described in this Chapter.
Once you are satisfied you can meet all the installation requirements, install the
transducer in accordance with the accompanying installation instructions.
Running transducer cable
Each transducer type has a 14 m (45 ft) cable fitted with spade terminals for
connection to the ST60+ Speed instrument. The manner in which you run the
cable will depend on the locations of the transducer and instrument.
Observing the following guidelines, run the transducer cable to the ST60+ Speed
instrument:
If the cable has to be fed through the deck, always use a proprietary deck
gland.
Where cables are fed through holes, always use grommets to prevent chafing.
Secure long cable runs so they do not present a hazard.
Do not route the cable through bilges.
Wherever possible, route the cable away from fluorescent lights, engines,
radio transmitting equipment, as these may cause interference.
Although the transducer cable is fitted with spade connectors for direct con-
nection to the rear of the instrument, it may be necessary to remove these to
facilitate installation, e.g. if the cable has to be routed through narrow aper-
tures. Extra spade connectors are provided, to replace any that are removed
when running the cable. When fitting spade connectors, prepare the cable as
at (a) in the following illustration, then fold back the wire strands and insert
into the spade connector as at (b). Ensure the wire strands do not extend
beyond the rear of the spade connector insulation, then crimp the connector
to the wire.
3 mm
6 mm
50 mm
(a)
(b)
D4467-6
81261_1.book Page 20 Tuesday, November 29, 2005 12:42 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raymarine ST60+ SPEED INSTRUMENT and is the answer not in the manual?

Raymarine ST60+ SPEED INSTRUMENT Specifications

General IconGeneral
BrandRaymarine
ModelST60+ SPEED INSTRUMENT
CategoryMarine Equipment
LanguageEnglish

Related product manuals