EasyManua.ls Logo

Raytech TR–Mark III 250V - Technical Specifications; Measurement Parameters and Accuracy

Raytech TR–Mark III 250V
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual TR-Mark III 250V Version 1.10 Preliminary Page 43 of 57
9 Technical Specification
Measurement Parameters
Ratio: Resolution: 5 Digits
250V Range
0.8 ... 5000 ±0.06% Rdg ±1 LSD
5001…10,000 ±0.1% Rdg ±1 LSD
10,001.. 32,500 ±0.3% Rdg ±1 LSD
32,501…40,000 ±0.4% Rdg ±1 LSD
100V, Range Accuracy at 100 V or 40 V
40V 0.8 ... 2000 ±0.06% Rdg ±1 LSD
2001 ... 4000 ±0.1% Rdg ±1 LSD
4001 ... 13000 ±0.3% Rdg ±1 LSD
13000 ... 16000 ±0.4% Rdg ±1 LSD
10V Range Accuracy at 10 V
0.8 … 500 ±0.1% Rdg ±1 LSD
501 … 1000 ±0.12% Rdg ±1 LSD
1001 … 3250 ±0.3% Rdg ±1 LSD
3251 … 4000 ±0.4% Rdg ±1 LSD
1V Range Accuracy at 1 V
0.8 … 50 ±0.1% Rdg ±1 LSD
51 … 100 ±0.15% Rdg ±1 LSD
101 … 325 ±0.3% Rdg ±1 LSD
326 … 400 ±0.4% Rdg ±1 LSD
Current:
Range Accuracy Resolution
0 ... 1A ±0.001 A 0.1mA
Phase Angle: Phase Range: ±90 Degree, Resolution: 0.01°
250V TR-Range Accuracy
0.8 ... 600 ±0.05°
601 … 5,000 ±0.10°
5,001…10,000 ±0.15°
10,001…32,500 ±0.40°
32,501…40,000 ±0.50°
100V TR-Range Accuracy
0.8 ... 240 ±0.05°
241 … 2000 ±0.10°
2001 ... 4000 ±0.15°
4001 ... 13000 ±0.40°
13000 ... 16000 ±0.50°
40V TR-Range Accuracy
0.8 ... 240 ±0.10°
241 … 2000 ±0.15°
2001 ... 4000 ±0.20°
4001 ... 13000 ±0.45°
13000 ... 16000 ±0.55°
10V TR-Range Accuracy
0.8 ... 60 ±0.15°
61 … 500 ±0.25°
501 ... 3250 ±0.55°
3251 ... 4000 ±0.65°
1V TR-Range Accuracy
0.8 ... 6 ±0.15°
7 … 50 ±0.25°
51 ... 325 ±0.55°
326 ... 400 ±0.65°

Table of Contents

Related product manuals