Code Name Setting range Default Min. Attri.
C3.48
Speed limitation reference selec-
tion at torque control mode
0: Parameter C3.38 and
C3.39
1: AI1
2: AI2
3: EAI1 analog input
4: Communication (Speed
limitation register: Modbus
0x7F05/Fieldbus exten-
sion card H0.16)
5: EAI2 analog input
0 - Stop
C3.49 Torque command ramp 0.0...5.0 s 0.0 0.1 Stop
C3.52
SVC regulation area lower frequen-
cy
0.00...600.00 Hz DOM 0.01 Stop
C3.53
SVC regulation area upper frequen-
cy
0.00...600.00 Hz DOM 0.01 Stop
C3.54
SVC dampfactor enhance upper
frequency
DOM DOM 0.01 Stop
C3.55
SVC dampfactor enhance coeffi-
cient
1...20 1 1 Stop
①
: percentage of motor rated torque.
*: All parameters in Group C3 are ONLY for Frequency Converter
VFC 5610.