Nr. Code Name Description
38 AibE
Analog input broken wire de-
tection
Analog input wire is disconnected
39 EPS- DC_IN power supply error DC_IN power supply voltage is out of range 20...28 V
40 dir1 Forward running lock error Direction can only be forward but command is reverse
41 dir2 Reverse running lock error Direction can only be reverse but command is forward
42 E-St Terminal error signal Error signal is received from digital inputs
43 FFE- Firmware version mismatch
Firmware version of panel or extension card does not
match that of control board
44 rS- Modbus communication error Modbus communication is not working properly
45 E.Par Parameter settings invalid
Parameter settings are invalid after firmware update or
extension card removed
46 U.Par
Unknown parameter restore
error
An unknown parameter is skipped during parameter
restore
48 idA- Internal communication error
Internal error caused by communication interference
or circuit connection problem
49 idP- Internal parameter error Internal error caused by parameter handling
50 idE- Converter internal error Converter has internal error, contact with service
51 OCd- Extension card internal error
Extension card was successfully detected by the de-
vice at startup, but the communication failed after-
wards
52 OCc
Extension card PDOs configu-
ration error
Process data configuration error for field bus commu-
nication
53 Fdi- no valid process data
No valid process data is received from remote commu-
nication server
54 PcE-
Remote control communica-
tion error
Error if communication to IndraWorks/Converter-
Works is lost during remote control
55 PbrE
Parameter backup / restore
error
Error occurs during parameter backup and restore op-
eration
56 PrEF
Parameter restore error after
firmware update
Error occurs if parameter settings cannot be restored
after firmware update
60 APE- Application firmware error
Error message if the application firmware was not loa-
ded correctly or trail use is over
61 APE1 Application error 1
Error which can be thrown by the application, descrip-
tion in application manual
62 APE2 Application error 2
63 APE3 Application error 3
64 APE4 Application error 4
65 APE5 Application error 5
Rexroth Frequency Converter VFC
3610 / VFC 5610
89/91
Diagnosis
R912005518_Edition 16 Bosch Rexroth AG

Table of Contents