4.2.2 Auto Pro Setup
Users can set processing parameters,G code attributes etc.under this menu.
Auto Pro Setup chart
1. Work Speed:Unit:mm/minute
Including work speed and fast speed,system default is 3000 mm/minute.
2. Safe Height:Unit:mm
The height of Z axid rise during processing. system default is 40.000 mm.
3. Auto Scale:
Actual processing speed=work speed*auto scale,system default auto scale does
not affect the fast speed.
4. Fall Scale:
Fall scale, system default is 0.200.fall speed=fast speed*fall scale, the
AUTO PRO SETUP
Work Speed
Safe Height
Auto Scale
Fall Scale
Stop Statue
G Code Setup
Pro Attribute
Work Array