1. Languages:
Change system display language,users can choose Chinese and English.
2. Data Initial:
After data initial system parameters will restore to factory setting.
3. Inner Format:
Wipe the internal files,it will not damage the system parameters.
4. Wipe Cache:
Users need to do this after functional upgrade, such as change four-axis
program to three-axis program,users must do this operation.After this operation ,users
need to restart the system.
5. Function Confi(Function Configuration):
Set whether the system retain a function or not, change it according to the actual
application in accordance with the practical application of changes.After the operation
users need to restart the system.
PS:Blue parts indicate system default function.
Setting:Press“ ”/“ ” move cursor to where users want to modify,
press“ ”,and then select the function users want,press “ ” to save.
Set function
PausePkup NoPick/Pickup
ScaleFast None/Affect
Manual Step/Trad
Pretrt Parse/None
QuryPara Query/None
StrtHome Query/Auto/ZOnly/None
CopyWork Off/On
RetOrgPZ Pick Z/Z Stop
TolstAct Pickup/Origin
PauseRstr All/only Z