PM Table
SM 2-3 D017/D018/D019/D020
Preventive
Maintenance
EM 120K 240K 360K NOTE
Dust collection box C C C C Remove, empty, clean
EM 120K 240K 360K NOTE
FUSING UNIT AND PAPER EXIT
Fusing Entrance and
Exit Guide Plates
C C C Clean with water or alcohol.
Hot Roller R R R
Pressure Roller R R R
Fusing Thermistors R R R
Cleaning Roller C C C
Cleaning Roller
Bushings
C C C
Clean with water or alcohol.
Hot Roller Strippers R R R
Hot Roller and
Pressure Roller
Bushings
L L L L
Grease Barrierta JFE5 5/2
(A0289300)
Paper Exit Guide
Ribs
C C C Clean with water or alcohol.
OTHERS
Main Motor Drive
Gear
L I I I
Silicone Grease G501 (see
‘Main Motor Drive Gear’)
EM 120K 240K 360K NOTE
ADF (PM interval is measured in originals)