Image Problems
D017/D018/D019/D020 4-48 SM
2. Measure the height difference [B] between the hinge bracket [C] and scanner housing
[D].
3. If the difference is 0.5 mm or more:
Add a spacer (t = 0.5 to 0.8) between the hinge bracket (mainframe) and ADF left
hinge, to lift the left side of the ADF
-or-
Adjust the stepped height difference between the hinge bracket and scanner housing
until it is within 0 ±0.3 mm.
This is necessary because skew occurs when the hinge bracket more than 0.3
mm lower than the scanner housing.