SP1xxx: Feed
D017/D018/D019/D020 5-18 SM
correct this, increase the length of time the motor runs in
reverse to lower the tray (to do this, reduce the value of the
setting).
Failure to feed occurs when there is not enough pressure. To
correct this, increase the length of time the motor runs forward
to raise the tray. (to do this, increase the value of the setting).
How to Read These SP Codes
Each selection shows the paper size and a percentage that
indicates the amount of paper remaining in the tray when the
setting will take effect. For example, "B4,LG 70%" means the
setting will take effect when B4 or Legal size paper is loaded in
the tray and 70% of the paper remains in the tray.
The "Initial" notation in the display indicates the default value for
the setting. A positive number (+) indicates the length of time
(ms) the lift motor runs forward to raise the bottom plate and
increase pressure. A negative number (-) indicates the length of
time (ms) the lift motor runs in reverse to lower the bottom plate
and reduce pressure.
Please note that the "Initial" settings for some settings are
negative (reverse run time), others are positive (forward run
time).
Note: Before doing any adjustments with these SP codes, confirm that
the correct paper size has been selected for each tray with SP codes
1912, 1913, 1914, 1915.
1 A3, DLT:100%
---
56 A5T:70%->30%
To correct feed problems for a paper size, be
sure to set all four settings (100%, 70%,
30%, 10%) for each paper size that is
causing problems.
The "T" notation denotes "SEF" (Short Edge
Feed).
The "Y" notation denotes "LEF" (Long Edge
Feed)
1912 Tray 1: Auto Paper Size Detection