SP4xxx: Scanner
D017/D018/D019/D020 5-66 SM
4800
SBU ID Check Setting DFU
DF Shading Free Run
4802
Executes the scanner free run for shading movement with the exposure
lamp on or off. The free run moves the scanning lamp a short distance and
immediately returns it to its home position.
1 Lamp ON
2 Lamp OFF
Touch [ON] to start the free run
Be sure to touch "OFF" to stop the free run.
Home Position Adjustment
4803
Adjusts the home position of the exposure lamp.
[-1 to 1/0.1/0.1]
Returning to Scanner HP
4804
Moves the exposure lamp a short distance and immediately returns it to its
home position. Touch [Execute]> "Completed"> [Exit].
Moving from Scanner HP
4806
Moves the exposure lamp a short distance away from the home position
and stops.
Touch [Execute]> "Completed"> [Exit]
Do SP4804 to return the exposure lamp to its home position.
Note
This SP is done before shipping the machine to another location.
Turning the machine power off/on also returns the exposure lamp
to its home position.
4903* Filter Settings