Bit Switches
D361 94 SM
Communication Switch 0A (SP No. 1-104-011)
No Function Comments
0
Point of resumption of memory
transmission upon redialing
0: From the error page
1: From page 1
0: The transmission begins from the page
where transmission failed the previous time.
1: Transmission begins from the first page,
using normal memory transmission.
1-7 Not used Do not change the settings.
Communication Switch 0B (SP No. 1-104-012)
No Function Comments
0
Use of Economy Transmission
during a Transfer operation to
end receivers
0: Disabled, 1: Enabled
These bits determine whether the machine
uses the Economy Transmission feature when
it is carrying out a Transfer operation as a
Transfer Station.
1
Use of Economy Transmission
during a Transfer operation to
the Next Transfer Stations
0: Disabled, 1: Enabled
2
Use of Label Insertion for the
End Receivers in a Transfer
operation
0: Disabled, 1: Enabled
This bit determines whether the machine uses
the Label Insertion feature when it is carrying
out a Transfer operation as a Transfer Station.
3
Conditions required for Transfer
Result Report transmission
0: Always transmitted
1: Only transmitted if there was
an error
0: When acting as a Transfer Station, the
machine will always send a Transfer Result
Report back to the Requesting Station after
completing the Transfer Request, even if there
were no problems.
1: The machine will only send back a Transfer
Result Report if there were errors during
communication, meaning one or more of the
End Receivers could not be contacted.