Dedicated Transmission Parameters
SM 149 D361
Fax Option
Type 3350
D361
Switch 02
No Function Comments
1 0 1 0 24.0
1 0 1 1 26.4
1 1 0 0 28.8
1 1 0 1 31.2
If all bits are at ‘1’, the setting is
‘Disabled’
Other settings: Not used
4-7 Not used Do not change the settings.
Switch 03
No Function Comments
Inch-mm conversion before tx
Bit 1 Bit 0 Setting
0 0
Inch-mm conversion
available
0 1 Inch only
1 0 Not used
1 1 Disabled
0-1
The machine uses inch-based
resolutions for scanning. If “inch
only” is selected, the printed copy
may be slightly distorted at the other
end if that machine uses mm-based
resolutions.
If the setting is “Disabled”, the bit
switch setting is used.
DIS/NSF detection method
Bit 3 Bit 2 Setting
2-3
0 0 First DIS or NSF
(0, 1): Use this setting if echoes on
the line are interfering with the set-up
protocol at the start of transmission.
The machine will then wait for the